Real-Time Insight into Spontaneous and Plasma Enhanced Si Etching Processes with Semicon Process Solutions

real-time monitoring of etch processes (1)

Introduction

Optical spectroscopy and mass spectrometry are the primary technologies used for etch process characterization and monitoring. Optical techniques are desirable in production settings because of their non-invasive nature, but they are applicable only in specific cases and cannot address all chemistries and materials. By contrast, mass spectrometry is a powerful technique for analysis of any process gas. Integrating mass spectrometers requires careful consideration of differences in process flow, pressure and reaction time scales. These constraints have previously been addressed using quadrupole mass spectrometers (residual gas analyzers, RGAs). However, as the semiconductor industry incorporates more materials in highly complex stacks for design of the next-generation chips, the limited mass range and low mass resolution and sensitivity of RGAs create a situation where they are no longer able to meet all the challenges of integration.

Semicon Process Solutions

TOFWERK’s Semicon Process Analyzer is an electron ionization time-of-flight mass spectrometer that was developed specifically to overcome the limitations of RGAs. Semicon Process Solutions provide simultaneous detection of all ionized species with isotopic resolution, greater than 105 dynamic range and a mass spectral acquisition rates up to 1000 Hz. All process gas and etch products are monitored to guide process control action and to inform analytics and process intelligence. Immediate modifications of process conditions include optimizing flow rates and ratios, monitoring substrate temperature, or detection of process excursion from optimal conditions or malfunctions.

Spontaneous and Plasma Enhanced Etching of Silicon

In this proof-of-concept etch experiment with the TOFWERK Semicon Process Analyzer, two well-studied, semiconductor-relevant chemistries were investigated – spontaneous Si etching in XeF2 and plasma etching of Si in a CF4/O2 chemistry.

The Semicon Process Analyzer was connected to the process reactor through a ~1 meter bellow. In the spontaneous etch case, the analyzer was connected directly to the reactor chamber. For the plasma etch system, the analyzer was connected at the rough pump level. Process pressures were varied from approximately 3-400 mTorr (≈ mbar), with sample temperature ranging from 20 C to just over 200 C.

The expected etch reactions for both XeF2 and CF4/O2 conditions are shown below. Note that in a pure CF4 plasma, non-volatile carbon compounds accumulate on the sample surface, hindering surface chemistry and resulting in lower etch rates and rough surfaces.  Adding O2 to the etch gas results in the reaction of these non-volatile compounds and formation of CO2, greatly increasing the etch rate.

Spontaneous Etching of Si in XeF2

Si Etching with XeF2
(1) XeF2 -> XeF + F -> Xe + F2 ; Si + 2 F2 -> SiF4

Plasma Etching in a CF4 and CF4/O2 chemistry

Si etch reactions are shown below for a pure CF4 plasma (2) and (3) for a CF4/O2 mixture
(2) Si + CF4 -> SiF4 + C 
(3) Si + CF4 + O2 -> SiF4 + CO2

Experimental Results

Spontaneous Etch of Si with XeF2

Si samples (3 cm2) were inserted in an atomic layer deposition (ALD) reactor fitted with a XeF2 source with variable pulsing capability using Ar as a carrier gas.

Figure 1 shows all relevant species and their time variation as a XeF2 pulse is introduced in the reactor. Figure 2 displays the same data with varied pulse width. Detailed analysis of data in Figure 2 demonstrates that real-time optimization of the etch gas flux and resulting by-products is possible. Similarly, as in the ALD case, and more importantly in an atomic layer etching process, this points out the ability to determine the optimum time needed to purge out the by-products prior to initiating the next process cycle. Also, during process development and optimization such a capability permits detection of a transition from an etch-rate-limited mode to loading-limited conditions. An important observation is that despite the very small sample size, large signal counts are measured for all species. Based on previous results and published literature for this etch chemistry, etch rates significantly smaller than one monolayer per second are expected for these process conditions. Finally, with the time-of-flight technology of the Semicon Process Analyzer, all compounds  – whether known in advance or not – are recorded and stored for off-line analysis, understanding and forensics.

Figure 1: Spontaneous etching of silicon with XeF2. Figures 1a (top) and 1b (bottom) show the time evolution of the most abundant species as the etch gas is introduced in a pulsed mode (100ms and 0.5mbar in an Ar carrier gas).
Figure 2. Spontaneous etching of silicon with XeF2 showing the signal time variation of the most abundant species as the etch gas is introduced using pulses of different duration (0.5mbar in an Ar carrier gas).

 

Reactive Ion Etching of Si in a CF4/O2 Chemistry

Experiments were conducted in both a downstream microwave plasma etcher and a standard reactive ion etch chamber (RIE). In both cases, only cm-sized Si substrates were utilized. Runs using both pure CF4 and CF4/O2 etch mixtures were performed at varying pressures and substrate temperatures.

Figure 3 displays  typical low-mass data for a pure CF4 RIE etch run. Despite the simple etch chemistry and the most basic substrate, the collected spectrum is dense with peaks.

Figure 4 shows the time dependence of relevant species in the mass spectrum as the plasma is turned on and off and the O2 content in the CF4 plasma is increased.

Figure 3. Typical spectrum during a Si etch run in a pure CF4 plasma (400 W, 100 sccm CF4)
Figure 4. Time evolution of plasma and etch product species during a CF4 RIE process showing the effect of O2 addition on the etch rate. a. (top) Power: 400 W, 100 sccm CF4, variable flow of O2 (0, 20 sccm), b. (bottom) Power: 400 W, 100 sccm CF4, variable flow of O2 (0, 20, 40 and 60 sccm).

As expected, the abundance of etch products significantly increases with O2 content but ultimately reaches a maximum at ~ 40 sccm (figure 3b) and decreases beyond that value due to reactive species dilution. Of interest, as a result of small variations in O2 flow rates, we observe measurable oscillations in the etch product signal which become significant as we go beyond the optimum O2 concentration (max etch rate) and move into the reactive species deficient regime. Such behavior is probably not critical in thick layer etching but would need to be corrected for when processing nanostructured devices.

Semicon Process Solutions Record All Compounds and Isotopic Distributions with High Mass Accuracy

As demonstrated in this proof-of-principle example, even the simplest etch chemistry (i.e., Si in a CF4 plasma) yields complex mass spectra where assignment of the observed peaks is not always easy or possible.

To that end, we would like to illustrate the challenge to identifying the peak at 47 Th, as highlighted in Figure 3 within the red circle, to a specific etch gas or product specie. For the pure CF4 plasma chemistry and substrate at play, the only possible species should have combination of the input etch gas and substrate atomic constituents, C, F, and Si.

Using the composition finder function of the Semicon Process software gives the etch product SiF+, at 46.974 Th (383 ppm mass deviation from measured peak) as a possible assignment. Full mass spectral acquisition, however, allows detection of a small but measurable O2 signal which expands the possible species to oxygen containing compounds. The composition finder gives us CFO+ at 46.992 Th (0.2 ppm mass deviation from measure peak) as another match.

Assigning the correct specie to the peak at 47 Th in this case is paramount to better understanding of the etch chemistry but more importantly key to determining whether process integrity is acceptable or not; SiF+ being an expected etch product but CFO+ an unexpected impurity related specie. Figure 5.a summarizes these results. To further improve our mass assignment, we look at the isotopic distribution for the two possible species and their match to the experimental pattern. Fig 5.b shows the isotopic distribution for both species and it is evident that only CFO+ presents a good visual match. Armed with these two observations, the peak at ~ 47 Th is unambiguously assigned to CFO+ which can point to a possible leak (O2 flow meter or external) or other contamination sources.

Figure 5. Identification of peak at 47 Th in the spectrum acquired during Si etch in a pure CF4 plasma using the instrument’s high mass accuracy (left panel) and measured isotopic distribution peaks with expected position for the two possible species (right panel).

 

Conclusion

A mobile Semicon Process Analyzer connected to an etch reactor in a minimally invasive fashion has been shown to provide important process insights even for the simplest etch chemistry (CF4/O2) and the most basic substrate (Si). Demonstration of real-time monitoring of all volatile compounds with high mass accuracy and sensitivity and sub-second detection of process changes was shown. The Semicon Process Gas Analyzer’s ability to measure masses with very high accuracy and resolution is found to be critical in unambiguous species assignment. Intrinsic measurements of all species allow for on-line reactor health assessment and off-line data analysis for process optimization and failure analysis.

Learn More